164 research outputs found

    Automated system for noise-measurements on low-ohmic samples and magnetic sensors

    Full text link

    A 14b 200MS/s DAC with SFDR>78dBc, IM3

    Get PDF
    A 14-bit 200MS/s current-steering DAC with a novel digital calibration technique called dynamic-mismatch mapping (DMM) is presented. Compared to traditional static-mismatch mapping and dynamic element matching, DMM reduces the nonlinearities caused by both amplitude and timing errors, without noise penalty. This 0.14µm CMOS DAC achieves a state-of-the-art performance of SFDR>78dBc, IM

    1/f noise in magnetic Ni80Fe20 single layers and Ni80Fe20/Cu multilayers

    Get PDF
    We have investigated the room temperature 1/f noise of microstructured soft magnetic Ni80Fe20 films, showing the anisotropic magnetoresistance effect, and of Ni80Fe20/Cu magnetic multilayers, showing the giant magnetoresistance effect. We find that the 1/f noise in magnetic multilayers is considerably enhanced with respect to the noise of the single domain layer, which sets a limit on the usability of giant magnetoresistance materials for low-frequency applications

    Multicentre evaluation of the Naída Ci Q70 sound processor: Feedback from cochlear implant users and professionals

    Get PDF
    The aim of this survey was to gather data from both implant recipients and professionals on the ease of use of the Naída CI Q70 (Naída CI) sound processor from Advanced Bionics and on the usefulness of the new functions and features available. A secondary objective was to investigate fitting practices with the new processor. A comprehensive user satisfaction survey was conducted in a total of 186 subjects from 24 centres. In parallel, 23 professional questionnaires were collected from 11 centres. Overall, there was high satisfaction with the Naída CI processor from adults, children, experienced and new CI users as well as from professionals. The Naída CI processor was shown as being easy to use by all ages of recipients and by professionals. The majority of experienced CI users rated the Naída CI processor as being similar or better than their previous processor in all areas surveyed. The Naída CI was recommended by the professionals for fitting in all populations. Features like UltraZoom, ZoomControl and DuoPhone would not be fitted to very young children in contrast to adults. Positive ratings were obtained for ease of use, comfort and usefulness of the new functions and features of the Naída CI sound processor. Seventy-seven percent of the experienced CI users rated the new processor as being better than their previous sound processor from a general point of view. The survey also showed that fitting practices were influenced by the age of the user

    Consensus Panel on a Cochlear Coordinate System Applicable in Histologic, Physiologic, and Radiologic Studies of the Human Cochlea

    Get PDF
    Hypothesis—An objective cochlear framework, for evaluation of the cochlear anatomy and description of the position of an implanted cochlear implant electrode, would allow the direct comparison of measures performed within the various sub-disciplines involved in cochlear implant research. Background—Research on the human cochlear anatomy in relation to tonotopy and cochlear implantation is conducted by specialists from numerous disciplines such as histologists, surgeons, physicists, engineers, audiologists and radiologists. To allow accurate comparisons between and combinations of previous and forthcoming scientific and clinical studies, cochlear structures and electrode positions must be specified in a consistent manner. Methods—Researchers with backgrounds in the various fields of inner ear research as well as representatives of the different manufacturers of cochlear implants (Advanced Bionics Corp, Med-El, Cochlear Corp) were involved in consensus meetings held in Dallas, March 2005 and Asilomar, August 2005. Existing coordinate systems were evaluated and requisites for an objective cochlear framework were discussed. Results—The consensus panel agreed upon a 3-dimensional, cylindrical coordinate system of the cochlea using the “Cochlear View” as a basis and choosing a z-axis through the modiolus. The zero reference angle was chosen at the centre of the round window, which has a close relationship to the basal end of the Organ of Corti. Conclusions—Consensus was reached on an objective cochlear framework, allowing the outcomes of studies from different fields of research to be compared directly
    corecore